The aim of the project was to repair and do a corrosion treatment of 6 tubular spiral welded piles (800 mm diameter, 6 m high) in tidal conditions. The unique properties of Humidur® allow working in such conditions. The coating was applied at low tide in dry conditions but at a high relative humidity. High tide was not a problem as Humidur® can cure under water.
The treatment included following steps: blasting, welding, water jetting, grit-blasting, stripe coating and airless spraying of Humidur® anti-corrosion coating.
Year of treatment: 2012
Location: States of Guernsey St Peter Port, UK
Technical documents, data sheets, specification sheets and much more information are all available on www.humidur.be.