Inspection corroded sheet piles - Heerema Vlissingen B.V.

In 2005, Acotec coated a part of the sheet piles at Heerema Vlissingen B.V. The aim of the inspection in 2014 was to determine the effectiveness of the coating after ten years and to inspect the condition of the sheet piles.

· Date of execution: February 2014 - January 2015

· Name client: Heerema Vlissingen B.V., The Netherlands

The inspection was carried out by means of Acotec's DZI cofferdam in order to access the sheet piles below the waterline.

The inspections of the non-protected sheet piles showed corrosion both below and above the waterline. MIC caused pitting resulting in perforations of the sheet piles. The layer thickness was measured and mapped out:

Inspection corroded sheet piles - Heerema Vlissingen B.V.

The inspection of the ten-year old coating showed that the coating is still intact and performs well. No corrosion was detected at these places.

Inspection corroded sheet piles - Heerema Vlissingen B.V.

Jobreport

Humidur

Technical documents, data sheets, specification sheets and much more information are all available on www.humidur.be.

Member of:

Chinese Classification Society American Bureau of Shipping American Association of Port Authorities The European Small Hydropower Association The International Association of Ports and Harbors National Association of Corrosion Engineers  The World Association for Waterborne Transport Infrastructure The Society For Protective Coatings British Hydropower Association